Skip to content
LogIT Solutions LLC

Biometric reader accessories: everything a door needs besides the reader

A reader on its own does not open a door. It needs a lock, an exit button, power and, where security matters, a module on the safe side of the wall. We supply all of it for Suprema, Virdi, HID and HuAi readers, matched to your reader, and install it across the UAE.

Readers
Suprema, Virdi, HID, HuAi
Parts listed
26
Install
Across the UAE
Wiring per
Suprema guide

Accessories by job

Four pages cover the hardware every door needs. Each one has a chooser, a comparison and the full specs.

Door locks and brackets

An EM lock holds the door while it has power. The bracket depends on how your door opens and what it is made of. A door sensor tells the system the door is really shut.

See the parts we supply7

Enrolment scanners

A USB scanner on the HR or admin desk adds fingerprints and cards to the software, so nobody queues at the door to register.

See the parts we supply6

One door, all the parts

Here is one access-controlled door seen from both sides. The reader is the only part outside. Everything that opens the door sits on the secure side, each on its own power.

Swipe the drawing sideways to see both views.

Drawing of a door kit. Outside: the reader at about 137 cm. Inside: Secure I/O 2, EM lock and bracket, exit button, break-glass release, door sensor, three separate power supplies and a diode across the lock.

Every part in the list has its own page. Illustrative drawing, not to scale; wiring follows the Suprema BioEntry W3 installation guide.

Which accessory do I need?

Start from what the door has to do. Each row names the part, and the part links to its page.

Which accessory to pick for each need
Lock a normal single door600 lb EM lockEnough holding force for most offices, meeting rooms and store rooms.
Lock a main entrance or a heavy door1200 lb EM lockTwice the holding force for doors people push hard.
Lock a frameless glass doorU bracket or drop boltThe U clamp holds the lock plate without drilling the glass. A drop bolt suits doors that swing both ways.
Let people out without a card or fingerPush or no-touch exit buttonMounted inside by the door. No-touch suits clinics, kitchens and busy doors.
An emergency way out if the system failsBreak-glass releaseIt cuts power to the lock directly, without the reader or controller.
Know when a door is forced or left openDoor contact sensorA magnetic switch tells the system whether the door is really shut.
More needs: sensors, modules, lifts, power cuts, PoE, enrolment7
Which accessory to pick, more needs
Stop someone opening the door by pulling the reader off the wallSecure I/O 2The lock relay moves inside, on the secure side, as Suprema recommends.
Control two to four doors from one boxDM-20 Door ModuleUp to four doors, plus two Wiegand inputs for other card readers.
Limit which lift floors people can reachOM-120 Output Module12 relays, one per floor button, with BioStar 2.
Keep the door working in a power cut12 V supply with batteryThe battery carries the lock and module until the power returns.
Run a PoE reader where the switch has no PoEPoE injectorAdds power to the network cable. Never use PoE and a DC adapter together.
Enrol fingerprints at a desk into BioStar 2BioMini Plus 2The USB scanner Suprema supports. BioMini Slim and Combo are not supported.
Enrol staff cards at a deskDE-620 or OMNIKEY 5427 CKDE-620 for BioStar 2. OMNIKEY 5427 CK types HID card numbers into almost any software.
Works with Suprema, Virdi, HID and HuAi: parts by reader brand5
Accessories by reader brand
SupremaLock controlSecure I/O 2, DM-20 or CoreStation on the secure sideReader powerBS-12VDCPWR (12 V); BS-24VDCPWR for FaceStation 2; PoE on PoE modelsFingerprint enrolmentBioMini Plus 2 (BioStar 2)Card enrolmentDE-620 (BioStar 2.4 and later)Brand accessoriesIM-120 inputs, OM-120 lift control, BioEntry W3 tilting bracket
VirdiLock controlWe match the controller to the reader modelReader powerPer the reader datasheetFingerprint enrolmentFOH02, FOH02SC, FOH04Card enrolmentFOH02 card versions, FOH02SCBrand accessoriesEnrolment scanners listed here
HID AmicoLock controlAn access controller over OSDP or WiegandReader powerPer the reader datasheetFingerprint enrolmentNot needed: Amico readers enrol facesCard enrolmentOMNIKEY 5427 CK for HID Prox, iCLASS and Seos cardsBrand accessoriesAsk us for current HID mounting options
HuAiLock controlStandard door hardware matched to the reader wiringReader power12 V supply sized to the readerFingerprint enrolmentAsk us: depends on model and softwareCard enrolmentAsk us: depends on model and softwareBrand accessoriesHuAi publishes no accessory range
Every brandLock controlEM lock and bracket, exit button, door sensor, break-glass releaseReader powerSeparate supplies for reader, module and lockFingerprint enrolmentOr enrol at the reader itselfCard enrolmentMIFARE or proximity cards to match the readerBrand accessoriesDiode across the lock

Brand facts come from each maker's documents; generic door hardware is matched by LogIT. Send us your reader model and we confirm the full list before you order.

Controllers, I/O modules and brackets

Modules sit on the secure side and do the switching: the lock, extra doors, lift floors and alarm inputs. They connect to the reader over RS-485, a two-wire link that Suprema runs up to 1.2 km on AWG24 twisted pair.

Secure door module (1 door) · Suprema

Suprema Secure I/O 2

A small module that sits on the safe side of the door and switches the lock, so the reader on the outside wall never holds the wires that open the door. It talks to the Suprema reader over an encrypted link. Suprema recommends it, a DM-20 or a CoreStation wherever security matters.

  • Moves the lock relay to the secure side of the wall
  • Encrypted link to the Suprema reader
  • RS-485, OSDP V2 compliant
  • Ultra-compact: 36 x 65 x 18 mm
Specs (8)
Model
SIO2
Doors
1
Relay
1
Inputs
2
RS-485
1 channel, OSDP V2 compliant
Power
12 V DC, max 0.5 A
Size (W x H x D)
36 x 65 x 18 mm
Operating temperature
-20 to 50 °C
Product sheet

Secure door module (up to 4 doors) · Suprema

Suprema DM-20 Door Module

Controls up to four doors from one box on the secure side, over an encrypted link to a Suprema reader. It also has two Wiegand reader inputs, so you can add card readers from other makers.

  • Up to 4 doors from one module
  • 2 Wiegand inputs for third-party readers
  • Daisy-chain up to 32 doors and 8 biometric devices
  • RS-485, OSDP V2 compliant
Specs (9)
Model
DM-20
Doors
Up to 4
Relays
4
Inputs
4, plus 4 supervised inputs
Outputs
6
Wiegand
2 reader inputs
RS-485
1 channel, OSDP V2 compliant
Power
12 V DC, max 3.1 A
Size (W x H x D)
130 x 90.5 x 35.8 mm
Product sheet

12-relay output module (lift control) · Suprema

Suprema OM-120 Output Module

Adds 12 relay outputs to a Suprema system. Its main job is lift control: each relay enables one floor button, so people only reach the floors they are allowed on. Suprema lists up to 192 floors per lift with BioStar 2.

  • 12 relay outputs
  • Lift control with BioStar 2, up to 192 floors per lift
  • Up to 31 modules on one master device
  • RS-485, OSDP V2 compliant
Specs (8)
Model
OM-120
Relays
12
AUX inputs
2, dry contact
Lift control
Up to 192 floors per lift (BioStar 2)
Daisy chain
Up to 31 modules per master device
RS-485
1 channel, OSDP V2 compliant
Power
12 V DC, max 0.6 A
Size (W x H x D)
90 x 190 x 21 mm
Product sheet

12-input extension module · Suprema

Suprema IM-120 Input Module

Adds 12 inputs to a Suprema system for door sensors, alarm contacts and signals from other systems. Each input can be linked to a relay, and those links keep working if the module loses contact with its master device.

  • 12 inputs, TTL or supervised
  • Input-to-relay links keep working offline
  • Tamper input
  • Up to 31 modules on one master device
Specs (8)
Model
IM-120
Inputs
12, TTL or supervised
Relays
2
Tamper
1 input
Daisy chain
Up to 31 modules per master device
RS-485
1 channel, OSDP V2 compliant
Power
12 V DC max 0.2 A, or 24 V DC max 0.1 A
Size (W x H x D)
90 x 190 x 21 mm
Product sheet
D0 D1OUT

Reader interface converter

Wiegand converter

Wiegand is the common wiring standard readers use to send a card number to a controller. A converter connects a Wiegand reader to equipment that expects a different connection, or changes the card number format between them.

  • Connects readers and controllers that do not match
  • Changes Wiegand card formats
  • Checked against both devices before supply
Specs (3)
Input
Wiegand reader
Use when
Reader and controller do not match
Check
We confirm both ends before supply
Product sheet

Tilting wall bracket · Suprema

Suprema BioEntry W3 tilting bracket

Suprema's dedicated bracket for the BioEntry W3 face reader. It tilts the reader so the camera meets faces at the right angle for your wall and entrance. Suprema sells it separately from the reader.

  • Made for the BioEntry W3
  • Adjusts the face-reading angle
  • Sold separately from the reader
Specs (4)
For
Suprema BioEntry W3
Adjusts
Tilt of the reader (reading angle)
Suggested height
137 cm (Suprema, BioEntry W3)
Fitting tip
Do not over-tighten, or the angle cannot be changed
Product sheet

Cards and fobs for your readers

Most readers also take a card. Match the card to what your reader reads: 13.56 MHz MIFARE or 125 kHz proximity. We supply both, and the fobs that go with them.

Questions buyers ask

Planning a full system? See access control and our biometric readers.

What do I need to put a fingerprint or face reader on one door?

A reader, an electric lock with the right bracket, an exit button, a door sensor and power. Where security matters, add a Secure I/O 2 or DM-20 inside, so the lock is not wired to the reader on the outside wall. Escape routes also need a break-glass release.

Do the lock and the reader need separate power supplies?

Yes. Suprema's installation guide says to use a separate power supply for the Secure I/O 2, the electric lock and the reader, because devices sharing one supply may malfunction.

Why does my installer say I need a Secure I/O 2?

Because the reader sits outside, where anyone can reach it. Suprema does not recommend using a reader's internal relay where security matters, to prevent tampering. A Secure I/O 2, DM-20 or CoreStation on the secure side switches the lock instead.

Should I buy a 600 lb or a 1200 lb EM lock?

600 lb suits most single internal doors: offices, meeting rooms and store rooms. Choose 1200 lb for main entrances, heavy doors and doors that people push hard.

What is the difference between fail-safe and fail-secure?

A fail-safe lock opens when its power is cut; a fail-secure lock stays locked. EM locks are always fail-safe. Drop bolts come in both versions, and your fire consultant or Civil Defence approval decides which a door on an escape route needs.

Do you install accessories?

Yes. LogIT supplies, installs and supports readers and door hardware across the UAE. We match every part to your reader and door before we quote.

Send us your door list. We match every part to your reader.

Tell us the reader model, the door type and how many doors. We put together the lock, exit button, power and module, then supply and install it across the UAE.

WhatsApp us+971 50 889 5653
Company
LogIT Solutions LLC
Office
Dubai Silicon Oasis
In business
13+ years
Offices
UAE · India · Kenya