EM locks, brackets and drop bolts

An EM lock (electromagnetic lock) is a strong magnet on the door frame that holds a metal plate on the door while it has power. A 600 lb lock suits most single doors; main entrances take 1200 lb. The bracket depends on how your door opens. We supply and fit them with your reader across the UAE.

Holding force
600 lb or 1200 lb
Brackets
L, ZL and U
Parts listed
7

Which lock fits your door?

Two questions decide it: which way the door opens, and what the door is made of. The secure side is the inside, where the lock goes.

Which lock and bracket for each door
Opens away from the secure side (you push it to leave)EM lock, no bracketThe lock fixes straight under the top of the frame and the plate goes on the door.
Opens away from the secure side, but the frame top is narrowEM lock + L bracketThe L bracket gives the lock a flat face to sit on.
Opens towards the secure side (you pull it to leave)EM lock + ZL bracketKeeps the lock inside. Without it the lock would have to go on the outside.
Is frameless glassEM lock + U bracketThe U clamp holds the plate on the glass without drilling.
Is glass and swings both waysElectric drop boltAn EM lock needs a door that stops against the frame. A bolt does not.
Is a main entrance, heavy or pushed hard1200 lb EM lockAbout 540 kg of holding force instead of about 270 kg.
Must report when it is forced or left openAdd a door contact sensorA magnetic switch tells the reader or module whether the door is shut.
600 lb, 1200 lb or a drop bolt? Locks and brackets compared6
EM locks and drop bolt compared
EM lock, 600 lbHolding force600 lb (about 270 kg)Best forSingle internal doors: offices, meeting rooms, store roomsWhen power is cutOpens (fail-safe)BracketsL, ZL or U
EM lock, 1200 lbHolding force1200 lb (about 540 kg)Best forMain entrances, heavy or busy doorsWhen power is cutOpens (fail-safe)BracketsL, ZL or U
Electric drop boltHolding forceBolt into a strike plateBest forGlass doors that swing both waysWhen power is cutFail-safe or fail-secure, by versionBracketsStrike plate on the door

Which bracket for which door

Which bracket for which door
L bracketShapeLDoorOpens away from the lock side, narrow frame topWhat it doesGives the lock body a flat mounting face
ZL bracketShapeZ on the door, L on the frameDoorOpens towards the lock sideWhat it doesKeeps the lock on the secure side
U bracketShapeU clampDoorFrameless glassWhat it doesHolds the lock plate on the glass, no drilling

Locks, brackets, bolts and sensors

Every door part on this page, grouped by job. Swipe the rail or jump to a group. Each lock runs on 12 V from its own supply, separate from the reader, as Suprema advises.

2

EM locks

600 lb for most single doors, 1200 lb for main entrances and heavy doors.

Electromagnetic lock

EM lock, 600 lb

An electromagnetic lock that holds a single door shut with about 600 lb (270 kg) of force while it has power. It suits most office, meeting room and server room doors. No power means no hold, so the door opens in a power cut.

  • 600 lb holding force
  • Fail-safe: releases when power is cut
  • For most single internal doors
  • Pairs with L, U or ZL bracket
Specs (5)
Holding force
600 lb (about 270 kg)
Power
12 V DC from its own supply
Behaviour
Fail-safe: opens when power is cut
Doors
Single internal doors
Install with
Diode across the lock terminals
Product sheet

Electromagnetic lock

EM lock, 1200 lb

A stronger electromagnetic lock with about 1200 lb (540 kg) of holding force. Pick it for main entrances, heavy doors and doors that people push hard. Like every EM lock it releases when power is cut.

  • 1200 lb holding force
  • Fail-safe: releases when power is cut
  • For main entrances and heavy doors
  • Pairs with L, U or ZL bracket
Specs (5)
Holding force
1200 lb (about 540 kg)
Power
12 V DC from its own supply
Behaviour
Fail-safe: opens when power is cut
Doors
Main entrances, heavy or busy doors
Install with
Diode across the lock terminals
Product sheet
3

Brackets: one for each kind of door

Tell us how the door opens and what it is made of, and we send the lock with the right bracket.

EM lock bracket

L bracket for EM lock

An L-shaped bracket that gives the EM lock a flat place to sit when the top of the door frame is too narrow to fix it directly. Use it on doors that open away from the lock side.

  • For narrow door frames
  • Doors that open away from the lock side
  • Matched to the lock size
Specs (3)
Shape
L
Mounts
EM lock body to the door frame
Use when
The top of the frame is too narrow
Product sheet

EM lock bracket

ZL bracket for inward-opening doors

A two-part Z and L bracket that lets you mount the EM lock on the secure side of a door that opens towards it. Without it, the lock would have to go on the outside, where anyone can reach it.

  • For doors that open towards the lock side
  • Keeps the lock on the secure side
  • Z plate on the door, L plate on the frame
Specs (3)
Shape
Z (door) and L (frame)
Mounts
EM lock and plate on the secure side
Use when
The door opens towards the lock side
Product sheet

EM lock bracket

U bracket for glass doors

A U-shaped clamp that holds the EM lock's metal plate on a frameless glass door, without drilling the glass. Use it when the door leaf is all glass.

  • For frameless glass doors
  • Clamps on, no drilling into glass
  • Matched to the glass thickness
Specs (3)
Shape
U clamp
Mounts
EM lock plate to a glass door
Use when
The door leaf is frameless glass
Product sheet
2

Drop bolts and door sensors

A drop bolt locks the doors an EM lock cannot. A door sensor watches every door, whatever the lock.

Electric bolt lock

Electric drop bolt

A bolt in the top of the frame that drops into a strike plate on the door. It locks doors an EM lock cannot hold, such as glass doors that swing both ways. Drop bolts come in fail-safe and fail-secure versions.

  • Locks doors that swing both ways
  • Common on frameless glass doors
  • Fail-safe or fail-secure versions
Specs (4)
Locks by
Bolt into a strike plate on the door
Power
12 V DC from its own supply
Versions
Fail-safe or fail-secure
Use when
The door swings both ways
Product sheet

Door position sensor

Door contact sensor

A two-part magnetic switch: one part on the frame, one on the door. It tells the system whether the door is really shut, so you get an alert when a door is forced or left open.

  • Door forced and door held open alerts
  • Wires to a reader, Secure I/O 2 or input module
  • Surface or concealed versions
Specs (3)
Type
Magnetic contact (reed switch)
Parts
Switch on the frame, magnet on the door
Wires to
Door sensor input
Product sheet

Fitting notes

Three things every installer should do with an electric lock.

  1. 1

    Fit a diode across the lock

    It protects the relay from the spike the lock makes when it switches off. Suprema says to fit it close to the lock and to check its direction.
  2. 2

    Give the lock its own power supply

    Suprema says the lock, the Secure I/O 2 and the reader each need a separate supply. See power supplies.
  3. 3

    Wire the lock to release on fire alarm where required

    The fire alarm interface cuts the lock power. Which doors need it is set by UAE Civil Defence rules: confirm with your fire consultant.

Source for notes 1 and 2: Suprema BioEntry W3 installation guide

Door lock questions

Need the whole door? The door kit drawing shows every part in place.

Should I buy a 600 lb or a 1200 lb EM lock?

A 600 lb EM lock (about 270 kg of holding force) suits most single internal doors. Choose 1200 lb (about 540 kg) for main entrances, heavy doors and doors that people push hard.

Which bracket do I need for a glass door?

For a frameless glass door, a U bracket clamps the lock plate onto the glass without drilling. If the glass door swings both ways, use an electric drop bolt instead, because an EM lock needs a door that closes against the frame.

What is the difference between an L and a ZL bracket?

An L bracket gives the lock a mounting face when the top of the frame is too narrow. A ZL bracket is for doors that open towards the lock side: it keeps the lock on the secure side instead of the outside.

Fail-safe or fail-secure: which do I need?

A fail-safe lock opens when power is cut; a fail-secure lock stays locked. EM locks are always fail-safe. Drop bolts come in both versions, and your fire consultant or Civil Defence approval decides what an escape-route door needs.

Why fit a diode across the lock?

When a lock switches off, its coil sends a short voltage spike back down the wire. A diode across the lock terminals absorbs it and protects the relay. Suprema says to fit the diode close to the lock and to check its direction.

Does the lock release when the fire alarm goes off?

It can. The lock power is wired through the fire alarm interface, so the lock releases when the alarm triggers. Which doors must do this is set by UAE Civil Defence rules, so confirm with your fire consultant before installation.

Will an EM lock work with my Suprema, Virdi, HID or HuAi reader?

Yes. The lock is standard 12 V door hardware. What changes is what switches it: for Suprema, a Secure I/O 2, DM-20 or CoreStation on the secure side; for other brands, the access controller or relay we match to the reader.

Tell us about the door. We send the right lock.

Send a photo of the door or tell us which way it opens and what it is made of. We pick the lock, bracket and power, and fit them with your reader.

WhatsApp us+971 50 889 5653
Company
LogIT Solutions LLC
Office
Dubai Silicon Oasis
In business
13+ years
Offices
UAE · India · Kenya