Skip to content
LogIT Solutions LLC

Exit buttons and emergency door release

An exit button lets people leave an access-controlled door without a card or fingerprint. A push button is the simplest. A no-touch button opens with a wave. A break-glass release is the emergency way out: it cuts the lock power directly. Most doors need an exit button, and escape-route doors usually need a break-glass too.

EXIT
Types
Push, no-touch, break-glass
Parts listed
3

Which exit button do I need?

Pick the everyday way out first, then decide whether the door needs an emergency release as well.

Which exit button to pick for each need
A simple, low-cost way out for most doorsPush exit buttonPress to leave. No power needed at the button.
Nothing to touch: clinics, kitchens, labs, busy doorsNo-touch exit buttonWave a hand at the infrared sensor. Needs 12 V power.
A way out that works even if the system failsBreak-glass releaseIt cuts the lock power directly, with no reader or controller in the way.
An everyday exit and an emergency exit on one doorExit button + break-glassThe usual pair on escape-route doors. Both mount inside, by the door.
A button outdoors or in a wet areaAsk for a weather-rated modelStandard buttons are made for indoors. Tell us where it goes.

How each one is wired

An exit button asks the system to open the door. A break-glass release does not ask: it breaks the lock's power line, so it still works when the system does not.

Everyday exit: push or no-touch button

  1. 1

    Exit button

    Pressed or waved at, inside the door

  2. 2

    Exit input

    On the Secure I/O 2, DM-20 or reader

  3. 3

    Relay

    Switches the lock power off

  4. 4

    Door opens

    The lock re-locks when the door shuts

If the controller or module is down, the button cannot open the door. That is why escape routes add a break-glass.

Emergency exit: break-glass release

  1. 1

    12 V lock supply

    The lock has its own supply

  2. 2

    Module relay

    Normal locking and unlocking

  3. 3

    Break-glass

    Sits in the same power line

  4. 4

    EM lock

    Loses power and lets go

Break the glass and the power line is cut. The lock opens whatever the reader, module or software is doing.

Push, no-touch and break-glass compared3
Exit buttons and break-glass release compared
Push exit buttonHow you use itPressWired toExit inputPower at the buttonNone (dry contact)If the system failsCannot open the door
No-touch exit buttonHow you use itWave a handWired toExit inputPower at the button12 VIf the system failsCannot open the door
Break-glass releaseHow you use itBreak or pressWired toThe lock's power linePower at the buttonNoneIf the system failsOpens the door

Exit buttons and emergency release we supply

Both mount on the inside wall by the door, at a height everyone can reach.

2

Exit buttons

Push or wave to leave. The system releases the lock.

EXIT

Request-to-exit button

Push exit button

A button on the inside wall by the door. Press it and the system releases the lock so people can walk out without a card or fingerprint. It is the most common way out of an access-controlled door.

  • Simple, low cost
  • Wires to the exit input of the reader or module
  • Flush or surface mount
Specs (3)
Operation
Press to exit
Contact
Dry contact (no power needed)
Wires to
Exit button input
Product sheet

Request-to-exit button

No-touch exit button (infrared)

An infrared sensor that releases the door when you wave a hand in front of it, so nobody touches a shared button. It needs a small power feed, unlike a push button.

  • Wave to exit, nothing to touch
  • Good for clinics, kitchens and busy doors
  • Needs 12 V power
Specs (3)
Operation
Wave a hand (infrared)
Power
12 V DC
Wires to
Exit button input
Product sheet
1

Emergency door release

The last line: no software, no reader, just a break in the lock's power.

Emergency door release

Break-glass emergency door release

A green emergency unit beside the door. Break or press it and it cuts power to the lock directly, so the door opens even if the reader, controller or exit button fails.

  • Cuts lock power directly, no software in the way
  • Green, so it is not confused with a fire alarm call point
  • Resettable versions available
Specs (3)
Operation
Break or press to release
Wired
In the lock's power line
Colour
Green (door release)
Product sheet

Exit button questions

The button needs a lock to release. See EM locks and brackets, or the full door kit drawing.

Push or no-touch exit button: which should I choose?

A push button is the simplest and suits most doors. A no-touch (infrared) button opens with a wave of the hand, so it suits clinics, kitchens, labs and busy doors where people should not touch a shared button. It needs a small 12 V power feed.

Do I need a break-glass release?

On doors that are part of an escape route, usually yes. It lets people out even if the reader, controller or exit button fails, because it cuts the lock power directly. Your fire consultant or Civil Defence approval confirms which doors need one.

Can I use an exit button outdoors?

Use a weather-rated button for outdoor gates and wet areas; standard buttons are made for indoors. Tell us where the button goes and we pick a suitable model.

How is an exit button wired?

A push button is a dry contact (a simple switch with no power of its own) wired to the exit input of the reader, Secure I/O 2 or controller. When it is pressed, the system releases the lock. A no-touch button also needs 12 V power.

Why is a break-glass door release green?

Green marks a door release and red marks a fire alarm call point. Using green stops people confusing the two in an emergency.

Do exit buttons work with Suprema, Virdi, HID and HuAi readers?

Yes, exit buttons are standard door hardware. With Suprema, wire the button to the Secure I/O 2 or DM-20 when you use one, so the exit signal stays on the secure side of the door.

Count your doors. We send the buttons and fit them.