Access control power supplies and PoE

Three things at every door need power: the reader, the module that switches the lock, and the lock itself. Suprema says each gets its own supply, because devices that share one may malfunction. Put a battery on the lock supply and the door keeps working through a power cut.

Supplies per door
Reader, module, lock
Parts listed
4

Which supply do I need?

Go device by device. Each one in the left column gets the supply in the middle, and none of them share.

Which power supply for each device
A Suprema reader rated for 12 VBS-12VDCPWRSuprema's 12 V adapter, for the reader only.
A Suprema FaceStation 2 or FaceLiteBS-24VDCPWRSuprema moved these to 24 V for longer cable runs. Not the FaceStation F2.
A PoE reader, where the switch has no PoEPoE injectorOne network cable carries data and power. Never add a DC adapter as well.
A Secure I/O 2 or DM-20Its own 12 V supplySuprema rates the Secure I/O 2 at max 0.5 A and the DM-20 at max 3.1 A.
An EM lock or drop bolt12 V supply with batteryThe battery keeps the door working through a power cut.

How far can the power cable run?

Further at 24 V than at 12 V, and further on thicker cable. These are Suprema's limits for the BioEntry W3. AWG is the cable gauge: the smaller the number, the thicker the wire.

Source: Suprema BioEntry W3 installation guide

Maximum power cable length for the Suprema BioEntry W3
CableAt 12 V DCAt 24 V DC
16 AWG50 m150 m
18 AWG30 m136 m
20 AWG20 m90 m

Do not extend the cable of a plug-in adapter, and do not use a 2-wire CAT5 UTP pair for power. For long runs, use a power supply and 16 or 18 AWG cable.

Power supplies we supply

Plug-in adapters for the readers, boxed supplies for locks and modules, and PoE injectors.

2

Suprema power adapters

Plug-in adapters for Suprema readers. Match the voltage to the exact model.

12 V DC power adapter · Suprema

Suprema BS-12VDCPWR 12 V adapter

Suprema's 12 V plug-in power adapter for its readers. FaceStation 2 and FaceLite are the exceptions: Suprema specifies 24 V for those. Use it for the reader only; the lock and any Secure I/O 2 get their own supply.

  • 12 V DC adapter for Suprema readers
  • Not for FaceStation 2 or FaceLite (24 V)
  • Powers the reader only, as Suprema advises
Specs (5)
Part number
BS-12VDCPWR
Output
12 V DC
For
Suprema readers rated for 12 V
Not for
FaceStation 2, FaceLite (use 24 V)
Powers
The reader only
Product sheet

24 V DC power adapter · Suprema

Suprema BS-24VDCPWR 24 V adapter

The 24 V adapter Suprema specifies for FaceStation 2. Suprema moved FaceStation 2 from 12 V to 24 V so the power cable can run further. Use 24 V only on devices Suprema rates for it.

  • 24 V DC adapter for FaceStation 2
  • Longer power cable runs than 12 V
  • Not for devices designed for 12 V only
Specs (4)
Part number
BS-24VDCPWR
Output
24 V DC
For
FaceStation 2 (also FaceLite)
Note
FaceStation 2 is not the FaceStation F2
Product sheet
2

Lock supplies and PoE

Boxed supplies for locks and modules, and PoE injectors for readers powered over the network cable.

Access control power supply

12 V power supply with battery backup

A boxed 12 V supply for the lock or module, with a backup battery that keeps the door working through a power cut. We size the supply and battery to your lock and the backup time you need.

  • 12 V DC output
  • Backup battery for power cuts
  • Sized to your lock and backup time
Specs (3)
Output
12 V DC
Backup
Sealed battery, sized to order
Powers
EM lock, drop bolt or module
Product sheet
INPoE

Power over Ethernet injector

PoE injector

Adds power to a network cable so a PoE reader runs on one cable, when your network switch does not supply PoE. Never power a reader from PoE and a DC adapter at the same time.

  • One cable for data and power
  • For switches without PoE
  • Use PoE or DC, never both
Specs (3)
Powers
PoE readers over the network cable
Use when
Your switch has no PoE
Rule
Never PoE and DC power together
Product sheet

Power notes

Suprema's rules for powering its readers. We follow them on every door we fit.

  1. 1

    One supply per device

    Separate supplies for the Secure I/O 2, the electric lock and the reader. Shared supplies may cause malfunctions.
  2. 2

    PoE or DC, never both

    Do not connect a DC supply or adapter and PoE to the same device at the same time.
  3. 3

    Choose an adapter with headroom

    Use an IEC/EN 62368-1 approved adapter that supplies more power than the device draws. Suprema recommends a listed Class 2 power unit.

Source: Suprema BioEntry W3 installation guide

Power questions

See where each supply goes on the door kit drawing.

Which Suprema adapter do I need: 12 V or 24 V?

BS-12VDCPWR (12 V) for Suprema readers rated for 12 V. BS-24VDCPWR (24 V) for FaceStation 2 and FaceLite, which Suprema moved to 24 V. FaceStation 2 is a different model from FaceStation F2, so check the exact model name.

Can I power the reader with PoE?

Yes, on reader models with PoE: plug into a PoE network switch or add a PoE injector. Never connect a DC adapter and PoE to the same reader at the same time; Suprema warns against it.

How long does battery backup last?

It depends on the battery size and how much current the lock and module draw. Tell us how many hours the door must keep working and we size the supply and battery to match.

Why do the lock and the reader need separate power supplies?

Suprema says to use a separate supply for the Secure I/O 2, the electric lock and the reader, because devices sharing one supply may malfunction. The lock also makes voltage spikes when it switches, which the reader should not share.

How far can the power cable run?

For the BioEntry W3, Suprema lists up to 50 m on 16 AWG cable at 12 V, and up to 150 m at 24 V. Thinner cable gives shorter runs, and Suprema says not to extend the cable of a plug-in adapter.

Which supply does a Secure I/O 2 need?

Its own 12 V DC supply. Suprema rates the Secure I/O 2 at 12 V, max 0.5 A, and the DM-20 door module at 12 V, max 3.1 A.

Tell us the reader and the lock. We size the power.